Daikin RXS25C2VMB [157/246] Indoor unit

Daikin ARKS25CVMB [157/246] Indoor unit
Indoor Unit SiENBE04-401A
148 Removal Procedure
1. Indoor Unit
1.1 Removal of Air Filter
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. External features
If ON/OFF button is kept
pushing for 5 seconds, a
forced cooling operation will
be carried out for approx. 15
minutes.
2. Removing air filters
1
Pull protrusions on left
and right sides of panel
with fingers and open
front grille all the way.
2
Lift center section of air
filter and disengage
hooks.
Remove air filter by
pulling forward.
Left and right filters are
interchangeable.
To re-install, insert air filter
along the guide.
ON/OFF button
Operation
lamp (Green)
Intelligent Eye
Receiver
Home leave
lamp (Red)
Timer lamp
(Yellow)

Содержание