АМАТЕК AN-SGM28P24-400 [219/322] Configuration survival time

АМАТЕК AN-SGM28P24-400 [219/322] Configuration survival time
218 / 322
Open global MLD SNOOPING
Switch#configure terminal
Switch(config)#ipv6 mld snooping
Open a VLAN MLD SNOOPING
Switch#configure terminal
Switch(config)#ipv6 mld snooping vlan <vlan-id>
Close global MLD SNOOPING
Switch#configure terminal
Switch(config)#no ipv6 mld snooping
Close a VLAN MLD SNOOPING
Switch#configure terminal
Switch(config)#no ipv6 mld snooping vlan <vlan-id>
16.2.3 Configuration survival time
Configuring the lifetime of multicast groups
Switch#configure terminal
Switch(config)#ipv6 mld snooping group-membership-timeout <interval> vlan <vlan-id>
The unit of Interval is milliseconds
The lifetime of configuration query groups
Switch#configure terminal
Switch(config)#ipv6 mld snooping query-membership-timeout <interval> vlan <vlan-id>
The unit of Interval is milliseconds
16.2.4 configuration fast-leave
Start a VLAN fast-leave
Switch#configure terminal
Switch(config)#ipv6 mld snooping fast-leave vlan <vlan-id>