АМАТЕК AN-SGM28P24-400 [319/322] Configuring ipv6 neighbor discovery protocol

АМАТЕК AN-SGM28P24-400 [319/322] Configuring ipv6 neighbor discovery protocol
318 / 322
according to the VLAN
interface MAC address under
the three layer interface
27.4 Configuring IPv6 neighbor discovery protocol
27.4.1 Configuring the parameters of the RA message
The user can configure the interface whether to send RA messages and send RA messages
according to the actual situation, and configure the related parameters in the RA message to notify
the host. When the host receives the RA message, we can use these parameters to do the
corresponding operationThe parameters and meanings of configurable RA messages are shown in
table 1-4
Table 1-4 parameters and descriptions in RA message
parameter
describe
Cur Hop Limit
When the host sends the IPv6 message, it will fill the Hop Limit
field in the IPv6 header with the parameter value. At the same
time, the parameter value is also used as the Hop Limit field
value in the device reply message
Prefix Information
When the host on the same link receives the prefix information
of the device, it can perform stateless automatic configuration
and other operations
M flag
To determine whether the host uses stateful automatic
configuration to obtain the IPv6 address
If this flag is set to 1, the host will have state through automatic
configuration (e.g. DHCP server) to obtain IPv6 address;
otherwise, the stateless auto configuration to obtain IPv6
address, IPv6 address is generated according to their link layer
address and router prefix information release
O flag
To determine whether the host uses stateful automatic
configuration to obtain additional information other than the
IPv6 address
If you set the other configuration flag is 1, the host will have
state through automatic configuration (e.g. DHCP server) to
obtain information in addition to other IPv6 address; otherwise,
the stateless auto configuration for additional information
Router Lifetime
The time used to set the router that releases the RA message as
the default router for the host. According to the router survival
time parameter value in the received RA message, the host can
determine whether or not the router that publishes the RA
message will be the default router
Retrans Timer
When the device sends NS messages, the NS message is re sent
if the response is not received within the specified time interval
Reachable Time
When the neighbor unreachability detection to verify that a
neighbor, in time up to set, equipment up to that neighbor;
exceed the time set, if you need to send messages to neighbors,
neighbors will re confirm whether can reach
Link MTU
The MTU option is used in the RA message to ensure that all