Configuring member device SwitchC
Because the configuration of the member devices is the same, the configuration on Switch C
is similar to that of Switch A, and the configuration process is slightly better
Configuration management device SwitchB
# Configuration management VLAN
[SwitchB] cluster management-vlan 10
[SwitchB] interface ge1/2
[SwitchB-ge1/2] switch trunk vlan 10
[SwitchB] interface ge1/3
[SwitchB-ge1/3] switch trunk vlan 10
# Enabling global NDP and NTDP functions, and enabling ports ge1/2 and ge1/3 on the NDP,
NTDP functions
[SwitchB] ndp enable
[SwitchB] ntdp enable
[SwitchB] interface ge1/1
[SwitchB-ge1/2] ndp enable
[SwitchB-ge1/2] ntdp enable
[SwitchB] interface ge1/3
[SwitchB-ge1/3] ndp enable
[SwitchB-ge1/3] ntdp enable
# The aging time of the NDP message sent by the device is 200 seconds on the receiving
device
[SwitchB] ndp timer aging 200
# The time interval for configuring the NDP message is 70 seconds
[SwitchB] ndp timer hello 70
# The maximum number of hops collected by the configuration topology is 2 hops
[SwitchB] ntdp hop 2
# Configuring the first port of the collected device to forward the topology, the delay time of
collecting the request packets is 150ms
[SwitchB] ntdp timer hop-delay 150
# The delay time of collecting request packets of other ports forwarding topology is 15ms
[SwitchB] ntdp timer port-delay 15
# The configuration topology collects intervals of 3 minutes
[SwitchB] ntdp timer 3