АМАТЕК AN-SGM28P24-400 Руководство по интерфейсу командной строки CLI онлайн [140/322] 598614

АМАТЕК AN-SGM28P24-400 Руководство по интерфейсу командной строки CLI онлайн [140/322] 598614
139 / 322
eaps protected-vlan 1 1
eaps protected-vlan 1 2
eaps enable 1
SW loop 1 and SWA docking, control vlan111, protect vlan1, 2. Ring 2 and SWB docking, control
vlan222, protect vlan3333 (virtual VLAN, while the interface need to add). If you want to achieve
ring 1 and ring 2 data trans ring forwarding, you need to configure the command EAPs data-span
Configuration is as follows
vlan database
vlan 2
vlan 111
vlan 222
vlan 3333
interface ge1/1
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 111
interface ge1/2
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 111
interface ge1/3
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 222
switchport trunk allowed vlan add 3333 ###Add virtual VLAN 3333
interface ge1/4
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 222
switchport trunk allowed vlan add 3333 ###Add virtual VLAN 3333
eaps create 1
eaps mode 1 Master
eaps primary-port 1 ge1/1