eaps secondary-port 1 ge1/2
eaps control-vlan 1 111
eaps protected-vlan 1 1
eaps protected-vlan 1 2
eaps data-span 1
eaps enable 1
eaps create 2
eaps mode 2 Transit
eaps primary-port 2 ge1/3
eaps secondary-port 2 ge1/4
eaps control-vlan 2 222
eaps protected-vlan 2 3333 ###Here is the virtual protection VLAN
eaps data-span 2
eaps enable 2
SWB ring 2 and SW ring 2 butt, control vlan222, protect vlan1, 2Configuration is as follows
vlan database
vlan 2
vlan 222
interface ge1/10
switchport access vlan 2
interface ge1/27
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 222
interface ge1/28
switchport mode trunk
switchport trunk allowed vlan add 2
switchport trunk allowed vlan add 222
eaps create 2
eaps mode 2 Master
eaps primary-port 2 ge1/27