57 / 322
detection time interval is 5
seconds
no storm-constrain interval
The detection interval of
storm control is restored to the
default value
Interface
configuration mode
no storm-constrain
Delete the storm control
function of the interface
Interface
configuration mode
show storm-constrain
View storm control
information for all interfaces
Privileged
mode
show storm-constrain interface IFNAME
View the storm control
information of the interface
Privileged
mode
Configuration specification
(1)
View the storm control information description table of the interface
(2)
By executing the storm- constrain action command to configure the action of storm control,
project
describe
interface
Interface name
type
Message type (1) broadcast- broadcast message; (2) multicast-
multicast message; (3) unicast- unicast message
rate
Min- low threshold; max- high threshold
action
Storm control actions include (1) block- blocking messages; (2)
shutdown- closing the interface
punish-status
The message state of the current interface includes (1) block- when the
speed is greater than max-rate and the storm control action is a blocking
message, the state is a blocking message
(2) Normal - normal forwarding
(3) shutdown-When the rate is greater than max-rate and the storm control
action is to close the interface, the state is closed interface
trap
Alarm switch status
on/off
log
Log switch status
on/off
interval
The detection interval of storm control is in seconds, and the default
value is 5 seconds
last-punish-ti
me
Finally, the time of storm control punishment