Icom ID-1 [21/124] Installation and connections

Icom ID-1 [21/124] Installation and connections
New2001
14
2
INSTALLATION AND CONNECTIONS
2
Type-N CONNECTOR INSTALLATION EXAMPLE
15 mm
19
32 in 6 mm
1
4 in 3 mm
1
8 in
Slide the nut, washer,
rubber gasket and clamp
over the coaxial cable,
then cut the end of the
cable evenly.
Strip the cable and fold the
braid back over the clamp.
Soft solder the center
conductor. Install the
center conductor pin and
solder it.
Carefully slide the plug
body into place aligning the
center conductor pin on the
cable. Tighten the nut onto
the plug body.
q
w
e
r
15 mm
3 mm
6 mm
No space
Solder hole
Be sure the center conductor is
the same height as the plug body.
Clamp
Center
conductor
Washer
Nut Rubber gasket