8 | Configuration
Installer reference guide
131
CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
CAUTION
Make sure to activate the disinfection function when a third-party tank is installed.
# Code Description
[A.4.4.2] [2‑00] Operation day:
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday (default)
6: Saturday
7: Sunday
[A.4.4.1] [2‑01] Disinfection
0: No (default)
1: Yes
[A.4.4.3] [2‑02] Start time: 00~23:00, step: 1:00 (default:
23:00).
[A.4.4.4] [2‑03] Temperature target: fixed value (default:
60°C)
[A.4.4.5] [2‑04] Duration
Range 40~60 minutes (default: 40 minutes)
00.00 22.00 24.0001.00 23.00 t
T
DHW
T
H
T
U
[2-02]
[2-03]
[2-04]
T
DHW
Domestic hot water temperature
T
U
User set point temperature
T
H
High set point temperature [2-03]
t Time