Moxa EDS-518E-4GTXSFP-T [105/116] Snmp read write settings

Moxa EDS-518E-4GTXSFP-T [105/116] Snmp read write settings
Managed Ethernet Switch (UI_2.0_FW_5.x) Featured Functions
3-92
SNMP Read/Write Settings
SNMP Versions
Setting Description Factory Default
V1, V2c, V3, or
V1, V2c, or
V3 only
Specifies the SNMP protocol version used to manage the
switch.
V1, V2c
V1, V2c Read Community
Setting Description Factory Default
Max. 30 characters Specifies the community string to authenticate the SNMP agent
for read-only access. The SNMP agent will access all objects
with read-only permissions using this community string.
Public
V1, V2c Write/Read Community
Setting Description Factory Default
Max. 30 characters Specifies the community string to authenticate the SNMP agent
for read/write access. The SNMP server will access all objects
with read/write permissions using this community string.
Private
For SNMP V3, two levels of privilege are available for accessing the Moxa switch. Admin privilege provides
access and authorization to read and write the MIB file. User privilege only allows reading the MIB file.
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
No-Auth Allows the admin account to access objects without
authentication.
No
MD5-
Auth
Authentication will be based on the HMAC-MD5 algorithms.
8-character passwords are the minimum requirement for
authentication.
No
SHA-
Auth
Authentication will be based on the HMAC-SHA algorithms.
8-character passwords are the minimum requirement for
authentication.
No
Enable Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
Enable Enables data encryption using the specified data encryption key
(between 8 and 30 characters).
No
Disable Specifies that data will not be encrypted. No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
No-Auth Allows the admin account and user account to access objects
without authentication.
No
MD5-Auth Authentication will be based on the HMAC-MD5 algorithms.
8-character passwords are the minimum requirement for
authentication.
No
SHA-Auth Authentication will be based on the HMAC-SHA algorithms.
8-character passwords are the minimum requirement for
authentication.
No
Enable User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
Enable Enables data encryption using the specified data encryption key
(between 8 and 30 characters).
No
Disable No data encryption No