Moxa EDS-518E-4GTXSFP-T [30/116] Severity

Moxa EDS-518E-4GTXSFP-T [30/116] Severity
Managed Ethernet Switch (UI_2.0_FW_5.x) Featured Functions
3-17
System Events Description
Master Changed Master of the Turbo Ring has changed
Master Mismatch When the duplicate master (two or more) or non-master is set up, if any
Turbo Ring path/switch fails, the duplicate master switches will
automatically renegotiate to determine a new master.
RSTP Root Changed If the RSTP root has changed
RSTP Topo. Changed If any Rapid Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree)
Turbo Ring Break Turbo Ring path is disconnected
DI1 (OnOff) Digital Input 1 is triggered by an on to off transition
DI1 (OffOn) Digital Input 1 is triggered by an off to on transition
ABC-02 Status Detects if the ABC-02-USB-T is connected or disconnected to the switch
when the ABC-02-USB-T automatically imports/exports/backs-up the
configuration
Rate Limited On (Disable Port)
When the port is disabled due to the ingress throughput exceeding the
configured rate limit.
Rate Limited Off (Disable Port) The port disable function is off because it exceeds the traffic duration or the
user changes Port Disablemode to Drop Packetmode.
Web log in Any account has logged in to the web-based configuration console
Port Looping Port looping event is triggered
LLDP Table Change Nearly connected devices are changed and shown in the LLDP table
Login Failure Lockout The attempt to log in exceeds the threshold
Account Info Changed The account information has been changed
Configuration is Imported When the configuration is successfully imported
SSL Certification is Imported When SSL Certification is successfully imported
Fiber Check Warning* If the corresponding value of the fiber port status exceeds the threshold
defined by the Fiber Check function
MAC Sticky Violation Port Disable Any port with MAC sticky function is disabled because of a rule violation
*The Fiber Check Warning event is only supported by the EDS-518E series.
Four response actions are available on the EDS E series when events are triggered.
Action Description
Trap The EDS E series will send a notification to the trap server when an event is triggered.
E-Mail The EDS E series will send a notification to the email server defined in the Email Setting.
Syslog The EDS E series will record a syslog to syslog server defined in Syslog Server Setting.
Relay The EDS E series supports digital inputs to integrate sensors. When an event is triggered,
the device will automate alarms through the relay output.
Severity
Severity Description
Emergency System is unusable
Alert Action must be taken immediately
Critical Critical conditions
Error Error conditions
Warning Warning conditions
Notice Normal but significant condition
Information Informational messages
Debug Debug-level messages

Содержание

Похожие устройства

Скачать