4 Configuration DES-1210 Metro Ethernet Managed Switch User Manual
66
RMON > RMON Event Configuration
The RMON Event page contains fields for defining, modifying and viewing RMON events statistics.
Figure 4.111 - RMON > RMON Event Configuration
The RMON Events Page contains the following fields:
Index (1~ 65535): Displays the event.
Description: Specifies the user-defined event description.
Type: Specifies the event type. The possible values are:
None Indicates that no event occurred.
Log Indicates that the event is a log entry.
SNMP Trap Indicates that the event is a trap.
Log and Trap Indicates that the event is both a log entry and a trap.
Community: Specifies the community to which the event belongs.
Owner: Specifies the time that the event occurred.
Click Apply to add a new RMON event.
Security > Trusted Host
Use Trusted Host function to manage the switch from a remote station. You can enter up to ten designated
management stations networks by defining the IP address/Subnet Mask as seen in the figure below.
Figure 4.112 - Security > Trusted Host
To define a management station IP setting, click the Add Host button and type in the IP address and Subnet
mask. Click the Apply button to save your settings. You may permit only single or a range of IP addresses
by different IP mask settings, the format can either be 192.168.1.1/255.255.255.0 or 192.168.0.1/24. Please
see the example below for permitting the IP range
IP Address
Subnet Mask
Permitted IP
192.168.0.1
255.255.255.0
192.168.0.1~192.168.0.255