D-Link DGS-6608 — настройка команды mpls ldp hello-holdtime для интерфейсов [502/1106]

Превью страниц Страница 502 / 1106
D-Link DGS-6604 [502/1106] Default
DGS-6600 Series Switch m mpls ldp hello-holdtime
CLI Reference Guide
492
mpls ldp hello-holdtime
Use mpls ldp hello-holdtime command to configure the LDP link hello hold-time
for the interface. Use the no form of this command to restore the default value.
mpls ldp hello-holdtime SECONDS
no mpls ldp hello-holdtime
Default 15 seconds.
Command mode interface configuration mode.
Usage guideline This command can only be applied on a Layer 3 VLAN interface.
LDP sends a link hello message periodically to discover its directly connected
neighbors. LDP maintains a hold timer for each discovered neighbor. If the timer
expires without receipt of hello from the neighbor, LDP concludes that the
neighbor has failed.
Example This example shows how to configure the hello hold time of VLAN 10 interface to
30 seconds.
The user can verify their settings by entering show mpls ldp interface
command.
Syntax Description
SECONDS Specifies the link hello hold-time in seconds. THe range is 5-65535 seconds
Switch(config)# interface vlan10
Switch(config-if)# mpls ldp hello-holdtime 30