Supplementary system components and encoder system integration
7.4 Sensor Module Cabinet-Mounted SMC30
Manual
210 Manual, 01/2011, 6SL3097-4AC10-0BP2
CAUTION
The encoder supply can be parameterized to 5 V or 24 V. The sensor may be destroyed if
you enter the wrong parameters.
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
For details of how to parameterize the KTY temperature sensors, refer to the SINAMICS
S120 Function Manual (FH1) in the Chapter "Monitoring and protective functions/Thermal
motor monitoring".
DANGER
Risk of electric shock!
Only temperature sensors that meet the safety isolation specifications contained in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp".
If these instructions are not complied with, there is a risk of electric shock!