Icom IC-207H [73/80] Maintenance

Icom IC-207H [73/80] Maintenance
15
MAINTENANCE
68
PROBLEM POSSIBLE CAUSE SOLUTION REF.
Some memory channels
cannot be selected via the
microphone keypad.
The input channel number has not yet been pro-
grammed.
Rotate the tuning dial to check whether the
channel has been programmed or not.
p.29
Scan does not operate. Squelch is open.
The selected scan edge memory channels (e.g.
1 A and 1b) have the same frequencies (for pro-
grammed scan).
Only 1 memory channel is programmed or other
channels are set as skip channels.
Priority watch is activated.
Set the squelch to the threshold point.
Reset the scan edges.
Program other memory channels or cancel the
memory skip function in the desired channels.
Turn the function OFF.
p. 20
p. 40
pgs.
30, 42
p. 45
Transmission is automati-
cally cut off.
Time-out timer is activated. Set the timer to OFF. p. 59
Transmission continues
even when the PTT is re-
leased.
One-touch PTT function is activated. Turn the function OFF. p. 23
The function display shows
erroneous information.
The CPU is malfunctioning. Reset the CPU.
p. 69