Moxa WDR-3124A-EU-T [34/94] Oncell central manager settings

Moxa WDR-3124A-EU [34/94] Oncell central manager settings
WDR-3124A Web Console Configuration
3-11
OnCell Central Manager Settings
In the navigation panel, click Cellular Settings > OnCell Central Manager Settings to display the
configuration screen.
The following table describes the fields.
Field Description Default setting
OnCell Central
Manager
Select Enable to allow the OnCell Central Manager to connect to
the
WDR-3124A.
Disable
Manager IP Enter the public IP address for the OnCell Central server.
Auto reconnect
period
Specify the time (10 1000 seconds) the WDR-3124A is to wait
before re-connecting to the OnCell Central server.
10
Management
information port
Enter the port number to send status information to the OnCell
Central server.
Make sure that you enter the same port number as specified on the
OnCell Central server and that the port number is not alread
y used
by another service.
63201
Management
configuration port
Enter the port number to send configuration information to the
OnCell Central server.
Make sure that you enter the same port number as specified on the
OnCell
Central server and that the port number is not already used
by another service.
63202
Telnet port Enter the TCP listening port number for Telnet session initiated from
a host.
Make sure that the port number you specify is not already used by
another service.
63203