Yamaha NEOS 50 YN50 (2002) [152/161] Signalling system

Yamaha NEOS 50 YN50 (2002) [152/161] Signalling system
ELEC
SIGNALLING SYSTEM
7-22
3.Voltage
• Connect the pocket tester (20 V DC) on the
flasher relay .
SATISFIES THE
SPECIFIED VALUE
(12 V)
Cable (+) of tester

Brown
Cable (–) of tester

Fame ground
• Place the main switch on “ON”.
• Check if there is a voltage (12 V) on the
“Brown” cable and “Frame ground” of the
flasher relay terminal.
• Place the main switch on “ON”
Chek it there is a vollàge (12V) on the
“Brown / White” cable and “Frame ground”
of the flasher relay terminal.
Cable (+) of tester

White/Brown
Cable (-) of tester

Frame ground
SATISFIES THE
SPECIFIED VALUE
(12V)
4. Voltage
Connect the pocket tester (20VDC) on the
flaster relay.
5. Voltage
• Connect the pocket tester (20 V DC) on the
bulb holder receptacle.
On the indicator light (left):
Cable (+) of the tester

Chocolate
Cable (–) of tester

Frame ground
On the indicator light (right):
Cable (+) of tester

Dark Green
Cable (–) of tester

Frame ground
INCORRECT
The “TURN” is defective, change the hand-
lebar switch (left).
OUTSIDE SPECIFIED VALUE
The flasher relay is faulty, change
OUTSIDE SPECIFIED VALUE
The indicator relay is defective, change

Содержание

Скачать