MEAN WELL CLG-150-20A [27/100] Series

MEAN WELL HLP-40H-20 [27/100] Series
INPUT
OUTPUT
24
AC input voltage range 90~305VAC; 127~431VDC
AC inrush current (max.) Cold start, 50A at 230VAC Cold start, 55A at 230VAC Cold start, 70A at 230VAC
DC adjustment range ±10% rated output voltage (A-Type only)
Current adjustment range 60%~100%
Over current protection 95%~108% constant current limiting, auto-recovery
Over voltage protection 109%~150% rated output voltage
Setup, rise, hold up time 500ms, 80ms, 16ms at full load and 230VAC
Total harmonic distortion THD<20%
Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:1.5kVAC
Working temperature -40~+50
O
C (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13, GB19510.14, GB19510.1,
EAC TP TC 004 approved; Design refer to UL/EN60950-1, EN60335-1for HLN-40H/60H
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, GB17743, GB17625.1,
EAC TP TC 020
Connection
Input UL rated, SVT 18AWGx3C (30cm)
Output A-Type: UL rated, SVT 18AWGx2C (30cm) ; B-Type: UL rated, SVT 18AWGx4C (30cm)
Dimension (LxWxH) (mm) 161x 61.5x 35 181x 61.5x 35
Features
Constant voltage + constant current modes
Universal AC input (90 to 305VAC) / Full range
High efficiency up to 91%
Fully isolated plastic case with IP64 level
Class 2 power unit / Pass LPS
Suitable for dry, damp location
Suitable for LED lighting with independent applications
Protections:
Short circuit / Over current / Over voltage / Over temperature
Multiple models for choice:
A-Type: IP64 rated. Output voltage and constant current level
can be adjusted through internal potentiometer
B-Type: IP64 rated and
built-in 3 in 1 dimming function
(1-10VDC, PWM signal, or resistance)
3 years warranty
HLN-40H HLN-60H
HLN-80H
HLN-40H Series
HLN-60H Series
HLN-80H Series
Model No. Output Tol. R&N Effi.
HLN-40H-12 A 12V, 0~3.33A ±2.5% 150mV 86.5%
HLN-40H-15 A 15V, 0~2.67A ±2.0% 150mV 86.5%
HLN-40H-20 A 20V, 0~2.00A ±1.0% 150mV 87.5%
HLN-40H-24 A 24V, 0~1.67A ±1.0% 150mV 88.0%
HLN-40H-30 A 30V, 0~1.34A ±1.0% 200mV 88.5%
HLN-40H-36 A 36V, 0~1.12A ±1.0% 200mV 88.5%
HLN-40H-42 A 42V, 0~0.96A ±1.0% 300mV 88.5%
HLN-40H-48 A 48V, 0~0.84A ±1.0% 300mV 89.0%
HLN-40H-54 A 54V, 0~0.75A ±1.0% 300mV 89.0%
= A or B
Model No. Output Tol. R&N Effi.
HLN-80H-12 A 12V, 0~5.0A ±2.5% 150mV 88.0%
HLN-80H-15 A 15V, 0~5.0A ±2.0% 150mV 89.0%
HLN-80H-20 A 20V, 0~4.0A ±1.0% 150mV 90.0%
HLN-80H-24 A 24V, 0~3.4A ±1.0% 150mV 90.5%
HLN-80H-30 A 30V, 0~2.7A ±1.0% 200mV 91.0%
HLN-80H-36 A 36V, 0~2.3A ±1.0% 200mV 91.0%
HLN-80H-42 A 42V, 0~1.95A ±1.0% 200mV 91.0%
HLN-80H-48 A 48V, 0~1.7A ±1.0% 200mV 91.0%
HLN-80H-54 A 54V, 0~1.5A ±1.0% 200mV 91.0%
= A or B
Model No. Output Tol. R&N Effi.
HLN-60H-15 A 15V, 0~4.0A ±2.0% 150mV 87.0%
HLN-60H-20 A 20V, 0~3.0A ±1.0% 150mV 88.5%
HLN-60H-24 A 24V, 0~2.5A ±1.0% 150mV 89.0%
Model No. Output Tol. R&N Effi.
HLN-60H-30 A 30V, 0~2.0A ±1.0% 200mV 89.5%
HLN-60H-36 A 36V, 0~1.70A ±1.0% 200mV 90.0%
HLN-60H-42 A 42V, 0~1.45A ±1.0% 300mV 90.0%
HLN-60H-48 A 48V, 0~1.30A ±1.0% 300mV 90.5%
HLN-60H-54 A 54V, 0~1.15A ±1.0% 300mV 90.5%
= A or B
A
A
B
B
TUV
Rheinland
Produc t Safety
P S
E
TUV
Rheinland
Produc t Safety
P S
E
TUV
Rheinland
Produc t Safety
P S
E
1-10VDC
1-10VDC
1-10VDC
(B-Type)
(B-Type)
(B-Type)
se
ri
es
4
0~80
W

Содержание

Скачать