Qtech QSW-2870 [213/230] According to different destination please execute corresponding steps refer to the

Qtech QSW-2870 [213/230] According to different destination please execute corresponding steps refer to the
Chapter8 Reliability Configuration
8-31
For link switching manually, according to different type of RLINK group, it is divided into single point
mode manual switching and double point mode manual switching.
It needs the following requirements to realize main-standby switching.
There are master and slave interface in Resilient Link group.
It must allow to force switching for link state. The link state of master and slave links should be
linkup. (Master is up and slave is down, if want to force master to be down and slave to be up,
slave link must be linkup.)
Purpose
Use the operation in this section to configure other related parameters of RLINK. User
can choose which step to use according to your need. But first RLINK group or MLINK
group should be configured.
Process
According to different destination, please execute corresponding steps. Refer to the
following table.
Objective
Procedure
Configure to
main/backup link
switching of RLINK
group manually
1. Use command of configure to enter Global Configuration View;
2. Use command of rlink group rlink-group-number to enter RLINK
Configuration View;
3. Use command of manual-change to trigger link switching;
4. End.
Configure overtime
multiple value of
receiving the peer
end protocol packet
of RLINK group
1. Use command of configure to enter Global Configuration View;
2. Use command of rlink group rlink-group-number to enter RLINK
Configuration View;
3. Use command of receive-timeout timeout-value to configure
overtime multiple value of receiving the peer end protocol packet of
RLINK group ;
4. End.
Enable or disable
RLINK returning
function
1. Use command of configure to enter Global Configuration View;
2. Use command of rlink group rlink-group-number to enter RLINK
Configuration View;
3. Use command of reverse { enable | disable } to enable or disable
RLINK returning function ;
4. End.
Configure returning
time of RLINK group
1. Use command of configure to enter Global Configuration View;
2. Use command of rlink group rlink-group-number to enter RLINK
Attention: