Max # ckts running
R
W*
Define allowable maximum number of circuits as needed.
Sequence # C1
R
W*
See section 6.3.1 Circuit Staging Sequence
Sequence # C2
R
W*
See section 6.3.1 Circuit Staging Sequence
Chiller status after power failure
R
W*
Define chiller status after power faliure. If set "Disable", then chiller stays off
after power failure.
Pump ctrl
R
W*
See section 6.2 Pump selection
Pump var flow
R
W*
Set if the water pump diriven by variable frequency device.
Pump recirc tm
R
W*
Set the time for water circulation in the system.
Cool LWT 1
R
W
See section 6.1 LWT target setting
Cool LWT 2
R
W
See section 6.1 LWT target setting
Heat LWT 1
R
W
See section 6.1 LWT target setting
Heat LWT 2
R
W
See section 6.1 LWT target setting
Ice LWT
R
W
See section 6.1 LWT target setting
Start up DT
R
W*
See section 6.3.2 Unit capacity control.
Stage up DT
R
W*
See section 6.3.2 Unit capacity control.
Stage dn DT
R
W*
See section 6.3.2 Unit capacity control. Not recommend to change. May cause
frequently stop/start.
Shut dn DT
R
W*
See section 6.3.2 Unit capacity control. Not recommend to change. May cause
frequently stop/start.
Nominal water DT
R
W*
Not necessary to change with variable water flow.
EWT Max pulldown rate
R
W*
See section 6.3.2 Unit capacity control. Not necessary to change except when
problem happen.
Stage up tm
R
W*
Cycle timer between Circuit#1 and #2. Not necessary to change except when
problem happen.
Ice dly tm
R
W*
Optional control. See section 8.1 Ice mode
Light load stage dn
R
W*
Define the capacity for the circuit to stop when load is too light. Not
necessary to change except when problem happen.
High load stage up
R
W*
Define the capacity for the circuit to start when load is too light. Not
necessary to change except when problem happen.
LWT reset type
R
W
See section 6.1 LWT target setting
Max reset
R
W
See section 6.1 LWT target setting
Start reset DT
R
W
See section 6.1 LWT target setting
Max reset OAT in cool
R
W
See section 6.1 LWT target setting
Start reset OAT in cool
R
W
See section 6.1 LWT target setting
Max reset OAT in heat
R
W
See section 6.1 LWT target setting
Start reset OAT in heat
R
W
See section 6.1 LWT target setting
Soft load
R
W
Optional control. See section 8.7 Soft load control
Soft load begin cap lim
R
W
Optional control. See section 8.7 Soft load control
Soft load ramp
R
W
Optional control. See section 8.7 Soft load control
Current limit
R
W
Optional control. See section 8.3 Current limit control
Current limit type
R
W
Optional control. See section 8.3 Current limit control
Current limit setting
R
W
Optional control. See section 8.3 Current limit control
Current @20mA
R
W
Optional control. See section 8.3 Current limit control
Flex current limit
R
W
Optional control. See section 8.4 Flexible current limit control