DNS-6040M/DNS-6040 User’s Manual
86
UPS to the network. In Storage Manager, go to Toolkit
UPS
Management, and select Control UPS by SNMP, using the
following settings:
Probing interval and Delayed before shutdown
The system will use the time interval set for Probing
interval to check the status of the UPS. If an AC power
failure or a low battery warning occurs, the system will
wait for the time entered under Delayed before shutdown
before shutting down, unless the problem is remedied
during that time.
UPS IP address and UPS community
UPS equipped with SNMP faculties will be assigned
an IP address. Enter this IP address in the respective
column. In the SNMP user interface of the UPS terminal
certain communities will be registered, each community
containing one or more host names and IP addresses.
These hosts can be trusted and can read information from
the UPS. If you want to control the UPS via SNMP, you
must register
D-Link NAS Filer for Business
in one of
the communities listed, then enter the name of the
community in the UPS community
field.
UPS enterprise OID
This setting can be found in the MIB file of the UPS.
If the UPS supports SNMP access, the manufacturer has
added an MIB file to the documentation. Download the
file from the manufacturer’s web site if necessary. Look in
the file for the Private Enterprise Number. APC’s Private
Enterprise Number is 318, so the value of this field should
read 1.3.6.1.4.1.318, whereby 1.3.6.1.4.1 is static and
must not be changed. You can also use an SNMP program
such as HP OpenView to browse through the MIB file and
retrieve the Private Enterprise Number.