DNS-6040M/DNS-6040 User’s Manual
87
Battery Status OID
This setting refers to the battery status OID in the
MIB file. The value for the APC UPS is
1.3.6.1.4.1.318.1.1.1.2.1.1. Enter this value, or the short
form 1.1.1.2.1.1, if you are using an APC product.
Normal status
The battery status OID (see above) obtained from
the MIB file represents a number of states, e.g., 2 for
battery normal, 1 and 3 for unknown or battery low
respectively.
If you have entered values for items 4 and 5, the system
will probe the UPS in the interval chosen above and, if
irregularities in the battery status are detected, shut down
after the delay value entered.
Registered UPS event trap OID pairs
A UPS with SNMP faculties usually has a trap
function, used to detect anomalies in the UPS status
without waiting for the scheduled probing signal. Click
Edit trap to add or delete event trap OIDs for your UPS.