Daikin RXYQ22M7W1B [3/182] Specifications

Daikin RXYQ16M7W1B [3/182] Specifications
Inverter heat pump RXYQ5M7W1B, RXYQ8,10M8W1B
18
1
Systems Outdoor Units
2
1 Specifications
1-1 Survey 5-48HP
RXYQ-M 5 8 10 12 14 16
MODULES RXYQ5M 1
RXYQ8M 1
RXYQ10M 1
RXYQ12M 1
RXYQ14M 1
RXYQ16M 1
EQUIVALENT HORSEPOWER HP 5 8 10 12 14 16
NUMBER OF OUTDOOR UNITS 111111
NUMBER OF COMPRESSORS 122233
NUMBER OF CONNECTABLE INDOOR UNITS 8 13 16 19 20 20
MINIMUM CAPACITY INDEX 62.5 100 125 150 175 200
MAXIMUM CAPACITY INDEX 162.5 260 325 390 455 520
COOLING CAPACITY kW 14.0 22.4 28.0 33.5 40.0 44.5
HEATING CAPACITY kW 16.0 25.0 31.5 37.5 45.0 50.0
POWER INPUT Cooling kW 3.79 6.97 9.00 10.60 14.24 15.60
Heating kW 4.34 6.89 9.31 10.80 12.90 14.00
EER 3.69 3.21 3.11 3.16 2.81 2.85
COP 3.69 3.63 3.38 3.47 3.49 3.57
CAPACITY STEPS 202929293535
DIMENSIONS Height mm 1,600 1,600 1,600 1,600 1,600 1,600
Width mm 635 930 930 1,240 1,240 1,240
Depth mm 765 765 765 765 765 765
WEIGHT kg 160 230 230 260 300 300
RXYQ-M 18 20 22 24 26 28 30 32
MODULES RXYQ5M
RXYQ8M 1
RXYQ10M 12111
RXYQ12M 1 1
RXYQ14M 1 1
RXYQ16M 1112
EQUIVALENT HORSEPOWER HP 1820222426283032
NUMBER OF OUTDOOR UNITS 22222222
NUMBER OF COMPRESSORS 44455566
NUMBER OF CONNECTABLE INDOOR UNITS 2020223232323232
MINIMUM CAPACITY INDEX 225 250 275 300 325 350 375 400
MAXIMUM CAPACITY INDEX 585 650 715 780 845 910 975 1.040
COOLING CAPACITY kW 50.4 56.0 61.5 68.0 72.5 78.0 84.5 89.0
HEATING CAPACITY kW 56.5 63.0 69.0 76.5 81.5 87.5 95.0 100.0
POWER INPUT Cooling kW 16.00 18.00 19.60 23.30 24.60 26.20 29.90 31.20
Heating kW 16.20 18.60 20.10 22.20 23.30 24.80 26.90 28.10
EER 3.15 3.11 3.14 2.92 2.95 2.98 2.83 2.85
COP 3.493.393.433.453.503.533.533.56
CAPACITY STEPS 4141414646465151
DIMENSIONS Height mm 1,600 1,600 1,600 1,600 1,600 1,600 1,600 1,600
Width mm 1,860 1,860 2,170 2,170 2,170 2,480 2,480 2,480
Depth mm 765 765 765 765 765 765 765 765
WEIGHT kg 460 460 490 530 530 560 600 600