Daikin RXYQ22M7W1B [59/182] Capacity tables

Daikin RXYQ22M7W1B [59/182] Capacity tables
Inverter heat pump RXYQ5M7W1B, RXYQ8,10M8W1B
18
3
Systems Outdoor Units
58
3 Capacity tables
3-1 Cooling capacity
3-1-13 30HP
30HP
TC: Total capacity ; PI: Power input
Combination
(%)
Capacity index
Outdoor
air temp.
CDB
Indoor air temperature: CWB
14,0 16,0 18,0 19,0 20,0 22,0 24,0
TC PI TC PI TC PI TC PI TC PI TC PI TC PI
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
50 375 10 28.55.3734.06.2139.57.1142.37.5845.08.0550.59.0456.010.1
12 28.55.4434.06.3039.57.2242.37.6945.08.1850.59.2056.010.3
14 28.55.5134.06.3939.57.3342.37.8245.08.3250.59.3556.010.4
16 28.55.5834.06.4939.57.4542.37.9545.08.4650.59.5256.010.6
18 28.55.6634.06.5939.57.5742.38.0845.08.6050.59.6956.010.8
20 28.55.7434.06.6939.57.6942.38.2245.08.7650.59.8756.011.0
21 28.55.7834.06.7439.57.7642.38.2945.08.8350.59.9656.011.1
23 28.55.8734.06.8539.57.8942.38.4445.08.9950.510.156.011.4
25 28.55.9634.06.9739.58.0442.38.6145.09.2750.510.756.012.1
27 28.56.0634.07.2139.58.4842.39.1645.09.8650.511.356.012.9
29 28.56.4134.07.6439.59.0042.39.7245.010.550.512.156.013.8
31 28.56.7734.08.0939.59.5442.310.345.011.150.512.856.014.7
33 28.57.1534.08.5639.510.142.310.945.011.850.513.656.015.6
35 28.57.5434.09.0539.510.742.311.645.012.550.514.556.016.6
37 28.57.9634.09.5639.511.342.312.345.013.350.515.356.017.6
39 28.58.3934.010.139.512.042.313.045.014.050.516.356.018.7
3TW25792-1