Daikin RXYQ22M7W1B [89/182] Capacity tables

Daikin RXYQ22M7W1B [89/182] Capacity tables
Inverter heat pump RXYQ5M7W1B, RXYQ8,10M8W1B
18
3
Systems Outdoor Units
88
3 Capacity tables
3-2 Heating capacity
3-2-1 5HP
TC: Total capacity; PI: Power Input
Combination (%) Capacity index
Outdoor
air temp.
Indoor air temperature: °CDB
16.0 18.0 20.0 21.0 22.0 24.0
TC PI TC PI TC PI TC PI TC PI TC PI
°CDB °CWBkWkWkWkWkWkWkWkWkWkWkWkW
50 62.5
-19.8 -20.0 9.03 4.44 8.51 4.14 8.00 3.84 7.74 3.70 7.49 3.56 6.97 3.28
-18.8 -19.0 9.03 4.28 8.51 3.99 8.00 3.71 7.74 3.57 7.49 3.44 6.97 3.17
-16.7 -17.0 9.03 3.99 8.51 3.72 8.00 3.47 7.74 3.34 7.49 3.22 6.97 2.97
-14.7 -15.0 9.03 3.74 8.51 3.49 8.00 3.26 7.74 3.14 7.49 3.02 6.97 2.80
-12.6 -13.0 9.03 3.52 8.51 3.29 8.00 3.07 7.74 2.96 7.49 2.86 6.97 2.64
-10.5 -11.0 9.03 3.33 8.51 3.11 8.00 2.91 7.74 2.81 7.49 2.71 6.97 2.51
-9.5-10.09.033.248.513.038.002.837.742.737.492.646.972.45
-8.5 -9.1 9.03 3.16 8.51 2.96 8.00 2.77 7.74 2.67 7.49 2.58 6.97 2.39
-7.0 -7.6 9.03 3.05 8.51 2.86 8.00 2.67 7.74 2.58 7.49 2.49 6.97 2.31
-5.0 -5.6 9.03 2.90 8.51 2.72 8.00 2.55 7.74 2.46 7.49 2.38 6.97 2.21
-3.0 -3.7 9.03 2.78 8.51 2.61 8.00 2.44 7.74 2.36 7.49 2.28 6.97 2.12
0.0 -0.79.032.618.512.458.002.307.742.227.492.156.972.00
3.0 2.2 9.03 2.46 8.51 2.32 8.00 2.17 7.74 2.10 7.49 2.03 6.97 1.90
5.0 4.1 9.03 2.38 8.51 2.24 8.00 2.10 7.74 2.03 7.49 1.97 6.97 1.84
7.0 6.0 9.03 2.30 8.51 2.16 8.00 2.03 7.74 1.97 7.49 1.90 6.97 1.78
9.0 7.9 9.03 2.22 8.51 2.10 8.00 1.97 7.74 1.91 7.49 1.85 6.97 1.73
11.0 9.8 9.032.168.512.038.001.917.741.857.491.796.971.68
13.0 11.8 9.03 2.09 8.51 1.97 8.00 1.86 7.74 1.80 7.49 1.74 6.97 1.63
15.0 13.7 9.03 2.03 8.51 1.92 8.00 1.81 7.74 1.75 7.49 1.69 6.97 1.59
NOTE
1 is shown as reference
When selecting the unit models, avoid the Outdoor air temperature range shown by .