Daikin RXYQ10MY1K [144/310] Part 6 troubleshooting

Daikin RXYQ8MY1K [144/310] Part 6 troubleshooting
Si39-502A
Troubleshooting 133
Part 6
Part 6Part 6
Part 6
Troubleshooting
TroubleshootingTroubleshooting
Troubleshooting
1. Symptom-based Troubleshooting .......................................................136
2. Troubleshooting by Remote Controller ...............................................139
2.1 The INSPECTION / TEST Button.........................................................139
2.2 Self-diagnosis by Wired Remote Controller .........................................140
2.3 Self-diagnosis by Wireless Remote Controller .....................................141
2.4 Operation of The Remote Controllers Inspection /
Test Operation Button ..........................................................................143
2.5 Remote Controller Service Mode .........................................................144
2.6 Remote Controller Self-Diagnosis Function .........................................146
3. Troubleshooting by Indication on the Remote Controller ....................151
3.1 A0 Indoor Unit: Error of External Protection Device ...........................151
3.2 A1 Indoor Unit: PC Board Defect.........................................................152
3.3 A3 Indoor Unit: Malfunction of Drain Level Control System (S1L) ......153
3.4 A6 Indoor Unit: Fan Motor (M1F) Lock, Overload...............................155
3.5 A7 Indoor Unit: Malfunction of Swing Flap Motor (MA) .......................156
3.6 A9 Indoor Unit: Malfunction of Moving Part of Electronic
Expansion Valve (20E).........................................................................158
3.7 AF Indoor Unit: Drain Level above Limit..............................................160
3.8 AJ Indoor Unit: Malfunction of Capacity Determination Device ..........161
3.9 C4 Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................162
3.10 C5 Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes..........163
3.11 C9 Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........164
3.12 CJ Indoor Unit: Malfunction of Thermostat Sensor
in Remote Controller ............................................................................165
3.13 E1 Outdoor Unit: PC Board Defect ......................................................166
3.14 E3 Outdoor Unit: Actuation of High Pressure Switch ..........................167
3.15 E4 Outdoor Unit: Actuation of Low Pressure Sensor ..........................168
3.16 E5 Outdoor Unit: Compressor Motor Lock ..........................................169
3.17 E6 Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............170
3.18 E7 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................172
3.19 E9 Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................174
3.20 F3 Outdoor Unit: Abnormal Discharge Pipe Temperature ..................176
3.21 F6 Outdoor Unit: Refrigerant Overcharged.........................................177
3.22 H7 Outdoor Unit: Abnormal Outdoor Fan Motor Signal.......................178
3.23 H9 Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....179
3.24 J2 Outdoor Unit: Current Sensor Malfunction ....................................180
3.25 J3 Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31 or 32T) ..................................................................................181
3.26 J5 Outdoor Unit: Malfunction of Thermistor (R2T) for
Suction Pipe .........................................................................................182
3.27 J6 Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger Deicer...................................................183