01 Basic Parameters
Pr. Explanation Settings
Factory
Setting
01-00 Max. Operation Frequency
50.00~600.00Hz
60.00/
50.00
01-01 Output Frequency of Motor 1
0.00~600.00Hz
60.00/
50.00
01-02 Output Voltage of Motor 1
230V: 0.0V~255.0V
460V: 0.0V~510.0V
200.0
400.0
01-03 Mid-point Frequency 1 of Motor 1
0.00~600.00Hz
3.00
01-04 Mid-point Voltage 1 of Motor 1
230V: 0.0V~240.0V
460V: 0.0V~480.0V
11.0
22.0
01-05 Mid-point Frequency 2 of Motor 1
0.00~600.00Hz
0.50
01-06 Mid-point Voltage 2 of Motor 1
230V: 0.0V~240.0V
460V: 0.0V~480.0V
2.0
4.0
01-07 Min. Output Frequency of Motor 1
0.00~600.00Hz
0.00
01-08 Min. Output Voltage of Motor 1
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.0
0.0
01-09 Start-Up Frequency
0.00~600.00Hz
0.50
01-10 Output Frequency Upper Limit
0.00~600.00Hz
600.00
01-11 Output Frequency Lower Limit
0.00~600.00Hz
0
01-12 Accel. Time 1
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-13 Decel Time 1
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-14 Accel Time 2
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-15 Decel Time 2
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-16 Accel Time 3
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-17 Decel Time 3
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-18 Accel Time 4
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-19 Decel Time 4
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-20 JOG Acceleration Time
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0
01-21 JOG Deceleration Time
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
AC drive with power greater than 30HP: 60.00/60.0
10.00
10.0