Delta Electronics VFD037CH23A-21 [465/638] X0 x1 y1 x4
Chapter 16 PLC Function CH2000 Series
16-12
Ladder Diagram
Structure
Explanation Command Device
Multiple output
MPS
MRD
MPP
none
Output command of coil
drive
OUT Y, M
Basic command,
Application command
Basic command/
Application
command
Inverse logic INV none
16.4.3 The Edition of PLC Ladder Diagram
The program edited method is from left power line to right power line. (The right power line will be
omitted during the edited of WPLSoft.) After editing a row, go to editing the next row. The
maximum contacts in a row are 11 contacts. If you need more than 11 contacts, you could have
the new row and start with continuous line to continue more input devices. The continuous
number will be produced automatically and the same input point can be used repeatedly. The
drawing is shown as follows.
X0 X1 X2 X3 X4 X5
Y0
X11 X12 X13
X6 X7 X10 C0 C1
00000
00000
Row Number
The operation of ladder diagram is to scan from left upper corner to right lower corner. The output
handling, including the operation frame of coil and application command, at the most right side in
ladder diagram.
Take the following diagram for example; we analyze the process step by step. The number at the
right corner is the explanation order.
X0 X1 Y1 X4
M0
X3
M1
T0
M3
Y1
TMR T0 K10