Chapter 11 Summary of Parameter Settings CH2000 Series
11-6
5: Forward run and search for Z-pulse as check
point.
6: Forward run to home. Set ORG: ONOFF
as check point.
7: Reverse run to home. Set ORG: ONOFF
as check point.
8: Define current position as home.
Y
Set X to 0, 1, 2, 3, 6, 7 first.
0: reverse run to Z pulse
1: continue forward run to Z pulse
2: Ignore Z pulse
Z
When home limit is reached, set X to 2, 3, 4, 5,
6, 7 first.
0: display the error
1: reverse the direction
00-41 Homing by frequency 1
0.00~600.00Hz
8.00
00-42 Homing by frequency 2
0.00~600.00Hz
2.00
00-43
~
00-47
Reserved
00-48 Display Filter Time (Current)
0.001~65.535 sec
0.100
00-49 Display Filter Time (Keypad)
0.001~65.535 sec
0.100
00-50 Software Version (date)
Read only
#####
00-51
~
00-61
Reserved