Delta Electronics VFD037CH23A-21 — функция подсчета с использованием многофункционального входного терминала [591/638]

Превью страниц Страница 591 / 638
Delta Electronics VFD007CH23A-21 [591/638] Reset to 0
Chapter 16 PLC Function CH2000 Series
16-138
16-11 Counting Function via MI8
The Multi-function Input Terminal (MI8) can be used for single direction Pulse counting and provides
a maximum speed of 100K. To initiate MI8 for counting, simply set M1038 to ON and the count value
will be saved to D1054 and D1055 in 32bit signed decimal. When M1039 is ON, counting value will
reset to 0.
0
M1000
MOV
D0
D1054
MI8 current calculating value
MOV
D1
D1055
M0
(M1038)
MI8
M1
(M1039)
RESETMI8
END
11
13
15
Operation Monitoring
Opening Point (a)
MI8 current calculating value
Start counting
calculated value
 When PLC program M1038 and M1039 uses MI8 for counting function, the previous AC
motor drive setting of MI8 is disabled and have no function.