Delta Electronics VFD037CH23A-21 [254/638] Switch between multi step position and multi speed control
Chapter 12 Description of Parameter SettingsCH2000 Series
12-38
Settings Functions Descriptions
ON
MI -GNDx
ON
OFF
ON
Reset
ON
OFF
Voltag
e
Frequency
Setting
frequency
Time
Operation
command
29
Signal confirmation for
Y-connection
When is the contact is ON, the drive will operate by 1st V/f.
30
Signal confirmation for
-connection
When the contact is ON, the drive will operate by 2nd V/f.
31
High torque bias
32
Middle torque bias
33
Low torque bias
Refer to Pr.11-30~11-32 for details.
34
Switch between
multi-step position and
multi-speed control
When the contact is ON, the corresponding 15-step speed for the
multi-function inputs 1-4 will be 15 positions. (Refer to Pr.04-16 to
Pr.04-44)
Run
1
0
1
1
1
0
1
1
0
0
1
1
0
0
1
1
04-40 04-38
04-11
MI=d35
MI=d34
MI=d1
MI=d2
MI=d3
MI=d4
speed mode
speed mode
position mode
10-19
position
(Home)
multi-
position
13
multi-
position
12
12th step
speed
frequency
output
frequency

Содержание