Delta Electronics VFD037CH23A-21 [265/638] Ry15 p2 41 50 rw

Превью страниц Страница 265 / 638
Delta Electronics VFD007CH23A-21 [265/638] Ry15 p2 41 50 rw
Chapter 12 Description of Parameter SettingsCH2000 Series
12-49
Settings Functions Descriptions
RY13 P2-39 = 50 RW
The bit 9 at 2026-41
RY14 P2-40 = 50 RW
The bit 10 at 2026-41
RY15 P2-41= 50 RW
The bit 0 at 2026-41
Refer to Chapter 15-3-5 for more information
51
Output for
communication card
For communication output of communication cards
(CMC-MOD01, CMC-EIP01, CMC-PN01 and CMC-DN01)
physical
terminal
Setting of
related
parameters
Attribute
Corresponding
Address
RY1 P2-13 = 51 RW The bit 0 2640
RY2 P2-14 = 51 RW The bit 1 2640
P2-15 = 51 RW The bit 2 2640
MO1 P2-16 = 51 RW The bit 3 2640
MO2 P2-17 = 51 RW The bit 4 2640
MO3 P2-18 = 51 RW The bit 5 2640
MO4 P2-19 = 51 RW The bit 6 2640
MO5 P2-20 = 51 RW The bit 7 2640
MO6 P2-21 = 51 RW The bit 8 2640
MO7 P2-22 = 51 RW The bit 9 2640
MO8 P2-23 = 51 RW The bit 10 2640
52 Output for RS-485 For RS-485 output
53~62 Reserved
63 Advance Crane Output
This function needs to be used with Pr02-32~Pr02-34,
Pr02-57~Pr02- 62.
The brake will be released when output frequency and current
reach the setting level after brake delay time.
This function separates the brake control conditions into eight
parameters, which is suitable for complicated application
Please check advance crane output time sequence chart for
reference