Delta Electronics VFD037CH23A-21 — гибкие настройки функций крана для повышения эффективности [618/638]

Превью страниц Страница 618 / 638
Delta Electronics VFD450CH23A-00/-21 [618/638] Crane function
19-1
Chapter 19 Application of CH2000
Crane Application
More flexible settings of crane function are added to CH2000. One of the features is that
the checking conditions of mechanical brake can be set independently (by checking
frequency or current) or relatively (by checking frequency and current). In addition, the
open and close of mechanical brake also can be set independently, which means there can
be one set of checking conditions for mechanical brake open and one set for mechanical
brake close. These two sets can be different.
Crane function
Multi-functional output (MO= 42)
Crane function combines multi-function output and time sequence setting. This function
works through checking frequency and current to trigger mechanical brake. The output
torque and mechanical braking torque can be switched smoothly via brake delay time to
reduce the instability in the operation which can increase the efficiency and ensure the
safety for crane hoist system
Pr. Explanation Settings Factory settings
02-32 Brake Delay Time 0.000~65.000
sec.
0.000
02-33
Output Current Level Setting
for Multi-function External
Terminals
0~100% 0
02-34
Output frequency setting
for multi-function output
terminal
0.00~±60.00HZ 0.00
02-57
Multi-function output terminal:
Function 42: Brake Current
Checking Point
0~100% 0
02-58 Multi-function output terminal:
Function 42: Brake Frequency
Checking Point
0.00~±60.00HZ 0.00

Содержание

1610

Узнайте о новых функциях настройки крана, включая независимые условия проверки механического тормоза и многофункциональный выход для повышения безопасности и эффективности.