Delta Electronics VFD037CH23A-21 [590/638] For 1 second and repeats frequency switching

Превью страниц Страница 590 / 638
Delta Electronics VFD037CH23A-21 [590/638] For 1 second and repeats frequency switching
Chapter 16 PLC Function CH2000 Series
16-137
Diagram 2: When Slave 1 on-line status is detected, it will delay for 3 seconds before control
command is enabled.
17
M700
MOVP
D1121
K0
Node 0 online
TMR
K30
T0
Enable Control Delay
( M100 )
Enable Control
( M215 )
Reset
Enable Control Delay
Enable Control Delay
T0
T0
M100
MOVP
D1121
K0
( M207 )
Node 0 Servo On
( M200 )
Node 0 Ack
Enable Control
33
Internal node control mode
Internal node control mode
Diagram 3: Commanding Slave 1 to forward run in 30.00Hz for 1 second and reverse run in 60.00Hz
for 1 second and repeats frequency switching.
41
M300
MOV
D1122
K3000
TMR
K10
T10
Node 0 arrive
+30.00Hz
52
M301
MOV
D1122K6000
-60.00Hz
( M200 )
Rev
TMR
K10
T11
M250
M250
Node 0 arrive
64
M302
MOV
K1M300
K1
Enable control
+30.00Hz
Repeat
M100
73
M300
ROLP
K1
K4M300
Enable control
+30.00Hz
M301
T10 M100
T11
-60.00Hz
+30.00Hz
END
84
Reference command of Internal Node 0
Reference command of Internal Node 0