Delta Electronics VFD037CH23A-21 — управление частотным приводом: Примеры и настройки [564/638]

Превью страниц Страница 564 / 638
Delta Electronics VFD450CH23A-00/-21 [564/638] K3000 30 0hz acceleration time is 50 and deceleration time is 60
Chapter 16 PLC Function CH2000 Series
16-111
Example
1. M1025: controls RUN (On)/STOP (Off) of the drive. M1026: operation direction
FWD (On)/REV (Off) of the drive. M1015: frequency attained.
2. When M10=ON, setting frequency command of the AC motor drive to
K300(3.00Hz) and acceleration/deceleration time is 0.
3. When M11=ON, setting frequency command of the AC motor drive to
K3000(30.00Hz), acceleration time is 50 and deceleration time is 60.
END
M13
M1044
M14
M1052
FREQP K300 K0 K0
FREQ
K3000 K50 K60
M11
M10
M10M11
M1000
M1040
M12
M1042
M1000
M1025
M11
M1026

Содержание