Delta Electronics VFD037CH23A-21 [205/638] Pr explanation settings factory setting

Превью страниц Страница 205 / 638
Delta Electronics VFD015CH23A-21 [205/638] Pr explanation settings factory setting
Chapter 11 Summary of Parameter Settings CH2000 Series
11-24
Pr. Explanation Settings
Factory
Setting
06-63 Fault Record 1 (Day)
0~65535 days
Read
only
06-64 Fault Record 1 (Min)
0~1439 min
Read
only
06-65 Fault Record 2 (Day)
0~65535 days
Read
only
06-66 Fault Record 2 (Min) 0~1439 min
Read
only
06-67 Fault Record 3 (Day) 0~65535 days
Read
only
06-68 Fault Record 3 (Min) 0~1439 min
Read
only
06-69 Fault Record 4 (Day)
0~65535 days
Read
only
06-70 Fault Record 4 (Min) 0~1439 min
Read
only
06-71 Low Current Setting Level 0.0 ~ 6553.5 % 0.0
06-72 Low Current Detection Time 0.00 ~ 655.35sec 0.00
06-73 Treatment for low current
0 : No function
1 : Warn and coast to stop
2 : Warn and ramp to stop by 2nd deceleration time
3 : Warn and operation continue
0