Chapter 11 Summary of Parameter SettingsCH2000 Series
11-33
Pr. Explanation Settings
Factory
Setting
10-19 Positioning for Encoder Position 0~65535pulse 0
10-20
Range for Encoder Position
Attained
0~65535pulse 10
10-21 Filter Time (PG2) 0~65.535 sec 0.100
10-22 Speed Mode (PG2)
0: Electronic Frequency
1: Mechanical Frequency (base on pole pair)
0
10-23 Reserved
10-24 FOC&TQC Function Control 0~65535 0
10-25
FOC Bandwidth of
Speed Observer
1.0~100.0Hz 40.0
10-26 FOC Minimum Stator Frequency 0.0~2.0%fN 2.0
10-27
FOC Low-pass Filter Time
Constant
1~1000ms 50
10-28
FOC Excitation Current Rise
Time
33~100%Tr 100
10-29 Top Limit of Frequency Deviation 0.00~100.00Hz 20.00
10-30 Resolver Pole Pair 1~50 1
10-31 I/F Mode, current command 0~150%Irated (Rated current % of the drive)
40
10-32
PM Sensorless Observer
Bandwidth for High Speed Zone
0.00~600.00Hz 5.00
10-33 Reserved
10-34
PM Sensorless Observer
Low-pass Filter Gain
0.00~655.35 Hz 1.00
10-35 ARM(Kp) 1~3 1
10-36 ARM(Ki) 1~3 1
10-37 PM Sensorless Control Word 0000~FFFFh 0000
10-38 Reserved
10-39
Frequency when switch from I/F
Mode to PM sensorless mode.
0.00~600.00Hz 20.00
10-40
Frequency when switch from PM
sensorless observer mode to
V/F mode.
0.00~600.00Hz 20.00
10-41 I/F mode, low pass-filter time 0.0~6.0sec 0.2
10-42 Initial Angle Detection Time 0~20ms 5
10-43 PG card version 0~655.35
Read
only