Delta Electronics VFD037CH23A-21 [266/638] Output freq

Превью страниц Страница 266 / 638
Delta Electronics VFD370CH23A-00/-21 [266/638] Output freq
Chapter 12 Description of Parameter SettingsCH2000 Series
12-50
Advance crane Output Time Sequence Chart:
Fwd run comm .
Output freq .
MO 63=
Output freq P02 34 . >= -
and output
current P02 33>= -
Pr02 32-
Rev run comm .
Output freq .
MO 63=
Pr02 32-
Output freq P02 61 . >= -
and output
current P02 62>= -
Output freq P02 58 .<-
and output current<-P02 57
Output freq P02 62 .<-
and output current
<-P02 60
# Once the operating command is given, then when the output frequency and output current reach the
setting level, the brake will be released after brake delay time.
# During the operation, if the frequency command is less than the brake releasing frequency, reset manually
frequency command to MAX (brake releasing frequency, brake holding frequency) to operate.
# Once the brake is released, it will not be held unless a stop command is give or certain errors are
occurred.
# Once the stop operating command is given, then when the output frequency or output current is lower than
the setting level, the brake holding operation will hold immediately the brake without delay time.
#To FWD brake releasing: Send operating command then set output frequency >= Pr02-34 and set output
current >=Pr02-33, delay Pr02-32 to release brake.
#To REV brake releasing: Send operating command then set output frequency >= Pr02-61 and set output
current >=Pr02-59, delay Pr02-32 to release brake.
#To FWD brake holding: Send stop operating command and set output frequency < Pr02-58 or set
output current < Pr02-57, release immediately the brake.