Chapter 12 Description of Parameter SettingsCH2000 Series
92
12-
ON ON ON ON ON ON ON ON
ONONONON
ON
ON
ON
ON
ON
04-00
04-01
04-02
04-03
04-04
04-05
04-06
04-0
7
04-08
04-09
04-10
04-11
04-12
04-13
04-14
01-22
OFF
OFF
OFF
OFF
OFF
1
2
34
5
67891011
12
13 14 15
Multi-function
terminals
MI1~MI4
02-01~02-08
Frequency
Master Speed
JOG Freq.
2nd speed
1st speed
Jog Freq.
Multi-speed via External Terminals
Run/Stop
PU/external terminals
/communication
3rd speed
4th speed
Position command 1 (pulse)
Position command 2 (pulse)
Position command 3 (pulse)
Position command 4 (pulse)
Position command 5 (pulse)
Position command 6 (pulse)
Position command 7 (pulse)
Position command 8 (pulse)
Position command 9 (pulse)
Position command 10 (pulse)
Position command 11 (pulse)
Position command 12 (pulse)
Position command 13 (pulse)
Position command 14 (pulse)
Position command 15 (pulse)
Factory Setting: 0
Settings -32767~32767
Please refer to Pr.02-01~02-08 (Multi-function Input Command) for description on setting 34
(Switch between multi-step position and multi-speed control) and setting 36 (Enable multi-step
position learning function).
Multi-step position corresponding MI4 MI3 MI2 MI1 Multi-step speed corresponding
10-19 0 0 0 0 Positioning for Encoder Position
04-16 Position command 1 (pulse) 0 0 0 1 04-00 1
st
step speed frequency
04-18 Position command 2 (pulse) 0 0 1 0 04-01 2
nd
step speed frequency
04-20 Position command 3 (pulse) 0 0 1 1 04-02 3
rd
step speed frequency

Содержание