Chapter 12 Description of Parameter SettingsCH2000 Series
12-178
PI adjustment-manual gain
PI adjustment-auto gain
1. Pr. 11-01 value
2. set Pr.11-00 to bit 0=1
Pr.11-05
use to adjust the
stren gth o f ze ro-
servo lock
P
I
Hz
11-10
11-11
11-08
11-09
11-06
11-07
0Hz
11-02
5Hz 5Hz
P
I
Hz
11-05
11-04
0Hz
5Hz 5Hz
11-02
Bit 7=0: frequency is saved before power turns off. When power turns on again, the display
frequency will be the memorized frequency.
Bit 7=1: frequency is not saved before power turns off. When power turns ON again, the display
frequency will be 0.00Hz.
Bit 8=0: maximum speed for point-to-point position control is control by the setting of Pr.11-43.
Bit 8=1: maximum speed for point-to-point position control is control by the multi-step speed
setting of the external terminal device. When multi-step speed of the external device is set to 0,
the maximum operation speed will bet the setting of Pr.11-43.
Per Unit of System Inertia
Factory Setting: 400
Settings
1~65535256=1PU
To get the system inertia from Pr.11-01, user needs to set Pr.11-00 to bit1=1 and execute
continuous forward/reverse running.
Unit of induction motor system inertia is 0.001kg-m^2:
Power Setting Power Setting Power Setting
1HP 2.3 20HP 95.3 100HP 1056.5
2HP 4.3 25HP 142.8 125HP 1275.3
3HP 8.3 30HP 176.5 150HP 1900.0
5HP 14.8 40HP 202.5 175HP 2150.0
7.5HP 26.0 50HP 355.5 215HP 2800.0
10HP 35.8 60HP 410.8 300HP 3550.0
15HP 74.3 75HP 494.8
The base value for induction motor system inertia is set by Pr.05-38 and the unit is in 0.001kg-m^2.
ASR1/ASR2 Switch Frequency
Factory Setting: 7.00
Settings 5.00~600.00Hz
ASR1 Low-speed Bandwidth
Factory Setting: 10
Settings 1~40Hz (IM)/ 1~100Hz (PM)