Chapter 15 CANopen Overview C2000 Series
15-22
Index Sub Definition
Factory
Setting
R/W Size Note
10B: Operation command by
Pr. 00-21 setting
11B: Switch the source of
operation command
Bit 15 Reserved
2
Freq. command
(XXX.XXHz)
0 RW U16
Bit0 1: E.F. ON
Bit1 1: Reset
3 Other trigger 0 RW U16
Bit15~2 Reserved
0 Number DH R U8
1 Error code 0 R U16
2 AC motor drive status 0 R U16 Bit 1~0 00B: stop
01B: decelerate to stop
10B
: waiting for operation
command
11B: in operation
Bit 2 1: JOG command
Bit 4~3 00B: forward running
01B
: switch from reverse
running to forward running
10B
: switch from forward
running to reverse running
11B: reverse running
Bit 7~5 Reserved
Bit 8 1
: master frequency command
controlled by communication
interface
Bit 9 1
: master frequency command
controlled by analog signal
input
Bit 10 1
: operation command
controlled by communication
interface
Bit 15~11
Reserved
3
Freq. command
(XXX.XXHz)
0 R U16
4 Output freq. (XXX.XXHz) 0 R U16
5 Output current (XX.XA) 0 R U16
6 DC bus voltage (XXX.XV) 0 R U16
7 Output voltage (XXX.XV) 0 R U16
8
the current segment run by
the multi-segment speed
commend
0 R U16
9 Reserved 0 R U16
A Display counter valuec 0 R U16
B
Display output power angle
(XX.X°)
0 R U16
C
Display output torque
(XXX.X%)
0 R U16
D
Display actual motor speed
(rpm)
0 R U16
E
Number of PG feed back
pulses (0~65535)
0 R U16
F
Number of PG2 pulse
commands (0~65535)
0 R U16
2021H
10 power output (X.XXXKWH) 0 R U16
2022H 0 Reserved 0 R U16
1 Display output current 0 R U16