Chapter 16 PLC Function CH2000 Series
16-33
Function Code
Function Code
Description Supported Devices
01
Read coil status
Y, M, T, C
02
Read input status
X,Y,M,T,C
03
Read one data
T,C,D
05
Force changing one coil status
Y, M, T, C
06
Write in one data
T,C,D
0F
Force changing multiple coil status
Y, M, T, C
10
Write in multiple data
T,C,D
Only when PLC is at Stop status, PLC data can be read/write via communication device. When PLC
is at Run status, the communication address should be the mapping address, e.g. for Pr.04-00 it
maps to 0400H.
NOTE
When PLC function is activated, C2000 can Read/Write the PLC and drive’s parameter by different
addresses (pre-defined station number for the AC motor drive is 1, for PLC station number is 2)