Daikin RZQS100B7V3B [6/344] Part 8 removal procedure 91

Daikin RZQS100B7V3B [6/344] Part 8 removal procedure 91
SiBE27-702
Table of Contents v
3. Piping Diagrams..................................................................................261
3.1 Piping Symbol ......................................................................................261
3.2 Pair System ..........................................................................................262
3.3 Twin System.........................................................................................265
3.4 Triple System .......................................................................................268
3.5 Double Twin System ............................................................................270
3.6 Pipe Connection Diameters..................................................................272
3.7 Re-using Existing Field Piping..............................................................273
4. Wiring Diagrams..................................................................................279
4.1 Outdoor Unit .........................................................................................279
5. Switch Box Layout...............................................................................282
5.1 RZQ71B9, RZQS71·100B7V3B (Single phase) ...................................282
5.2 RZQ100~140C7, RZQS125·140C7V1B (Single phase).......................283
5.3 RZQ100~140B8W1B (Three phase)....................................................284
6. PCB Layout .........................................................................................285
6.1 RZQ71B9, RZQS71·100B7V3B (Single phase) ...................................285
6.2 RZQ100~140C7, RZQS125·140C7V1B (Single phase).......................287
6.3 RZQ100~140B8W1B (Three phase)....................................................288
Part 8 Removal Procedure ........................................................ 291
1. RZQ71B9, RZQS71·100B7V3B / RZQ100~140B8W1B .....................292
1.1 Removal of Outside Panels..................................................................292
1.2 Removal of Propeller Fan and Fan Motor ............................................293
1.3 Removal of Switch Box ........................................................................294
1.4 Removal of PC Board Assy (1) ............................................................296
1.5 Removal of PC Board Assy (2) ............................................................297
1.6 Removal of PC Board Assy (3) ............................................................299
1.7 Removal of Low Pressure Sensor, Electronic Expansion Valve,
and Others............................................................................................300
1.8 Removal of Thermistor .........................................................................302
1.9 Removal of Four Way Valve.................................................................304
1.10 Removal of Compressor.......................................................................305
2. RZQ100~140C7, RZQS125·140C7V1B..............................................306
2.1 Removal of Outside Panels..................................................................306
2.2 Removal of Propeller Fan and Fan Motor ............................................307
2.3 Removal of Switch Box ........................................................................308
2.4 Removal of PC Board...........................................................................309
2.5 Removal of Pressure Sensor, Electronic Expansion Valve,
and Others............................................................................................310
2.6 Removal of Thermistor .........................................................................311
2.7 Removal of Four Way Valve.................................................................312
2.8 Removal of Compressor.......................................................................313
Part 9 Precautions for New Refrigerant (R-410A) .................... 315
1. Precautions for New Refrigerant (R-410A) .........................................316
1.1 Outline ..................................................................................................316
1.2 Refrigerant Cylinders............................................................................318
1.3 Service Tools........................................................................................319

Содержание

Скачать