BSS 366T OmniDrive [50/112] Program functions

BSS 366T OmniDrive [50/112] Program functions
- 50 -
FDS-366T
There are 3 ways in which data can be stored, and these are indicated by the
store type message at the top of the display. To highlight the Store type
message, use the navipad 'v' key while a program number is highlighted. Once
highlighted, turn the rotary encoder to select the type of store you wish to use.
INT
This stores the program in the internal memory of the unit.
Prg
This stores the currently selected program to a PC card (if inserted) in the slot
at the front of the unit (in a 366T file format).
All
This stores all program data to a PC card (if inserted) in the slot at the front of
the unit (in a 366T file format).
The Program Lock can be applied to a program stored using any of these 3
methods.
NOTE: The edit flag ('*') appears when there are unsaved changes to a
program, compared to the initial status of the last recalled/stored program
(Internal memory only). When a program is stored to internal memory, the edit
flag will disappear.
If a program is stored to a PC card, then the flag will NOT disappear, since
there are differences between the last recalled/stored program (Internal), and
the current program.
Once the program name has been entered, the store type selected, and the
Program lock status cleared, pressing the STORE key again will prompt the
message "Store Locked?", asking whether the program should be stored with a
Program lock. Use the rotary encoder to turn the Lock on or off ("Locked?" or
"Unlocked?"). Once the Lock status is set, push the STORE key a final time to
commit the program to memory (or PC storage). The display will now default
back to the screen displayed before the STORE facility was accessed.
To exit from the store screen without storing a program, press the 'RECALL'
button.