Tp-Link T2600G-28MPS (TL-SG3424P) [340/379] Statistics

Tp-Link T2600G-28MPS (TL-SG3424P) [340/379] Statistics
RMON Group
Function
Alarm Group Alarm Group is configured to monitor the specific alarm variables. When
the value of a monitored variable exceeds the threshold, an alarm event is
generated, which triggers the switch to act in the set way.
The RMON Groups can be configured on the Statistics, History, Event and Alarm pages.
15.3.1 Statistics
On this page you can configure and view the statistics entry.
Choose the menu SNMPRMONStatistics to load the following page.
Figure 15-9 Statistics
The following entries are displayed on this screen:
Statistics Config
ID:
Enter the ID number of statistics entry, ranging from 1 to
65535.
Port:
Enter or choose the Ethernet interface from which to collect
the statistics.
Owner:
Enter the owner name.
Status:
Choose the status of statistics entry.
valid: The entry exists and is valid.
underCreation: The entry exists, but is not valid.
Statistics Table
Select:
Select the desired entry to delete the corresponding statistics
entry. It's multi-optional.
ID:
Displays the ID number of the statistics entry.
Port:
Displays the Ethernet interface from which to collect the
328

Содержание