Tp-Link T2600G-28MPS (TL-SG3424P) [337/379] Notification

Tp-Link T2600G-28MPS (TL-SG3424P) [337/379] Notification
If SNMPv1 or SNMPv2c is employed, please take the following steps:
Step
Operation
Description
1 Enable SNMP function globally. Required. On the SNMPSNMP ConfigGlobal
Config page, enable SNMP function globally.
2 Create SNMP View. Required. On the SNMPSNMP ConfigSNMP
View
page, create SNMP View of the
management agent. The default View Name is
viewDefault and the default OID is 1.
3
Configure
access level
for the User.
Create SNMP
Community
directly.
Required alternatively.
Create SNMP Community directly.
On the SNMPSNMP ConfigSNMP
Community
page, create SNMP
Community based on SNMP v1 and SNMP
v2c.
Create SNMP Group and SNMP User.
Similar to the configuration way based on
SNMPv3, you can create SNMP Group and
SNMP User of SNMP v1/v2c. The User
name can limit access to the SNMP agent
from SNMP network management station,
functioning as a community name. The
users can manage the device via the Read
View, Write View and Notify View defined in
the SNMP Group.
Create SNMP
Group and SNMP
User.
15.2 Notification
With the Notification function enabled, the switch can initiatively report to the management
station about the important events that occur on the Views (e.g., the managed device is
rebooted), which allows the management station to monitor and process the events in time.
The notification information includes the following two types:
TrapTrap is the information that the managed device initiatively sends to the Network
management station without request.
InformInform packet is sent to inform the management station and ask for the reply. The
switch will resend the inform request if it doesn’t get the response from the management
station during the Timeout interval, and it will terminate resending the inform request if the
resending times reach the specified Retry times. The Inform type, employed on SNMPv2c and
SNMPv3, has a higher security than the Trap type.