Chapter 12 Description of Parameter SettingsCH2000 Series
12-47
Settings Functions Descriptions
(Pr.06-23)
36
Error Output Selection 2
(Pr.06-24)
Active when Pr.06-24 is ON.
37
Error Output Selection 3
(Pr.06-25)
Active when Pr.06-25 is ON.
38
Error Output Selection 4
(Pr.06-26)
Active when Pr.06-26 is ON.
39
Position Attained
(Pr.10-19)
Active when the PG position control point reaches Pr.10-19.
40
Speed Attained
(including zero speed)
Active when the output frequency reaches frequency setting or
stop.
41 Multi-position Attained
User can set any three multi-function input terminals to 41. The
current position action status of these three terminals will be
outputted. Example: if setting Pr.02-36~02-38 to 41 and only the
multi-position of the second point has been done. Therefore,
current status is RA (ON), RA (OFF) and MO1 (OFF). In this way,
their status is 010. Bit0 is RA and so on.
MO2
Pr.02-17=41
MO1
Pr.02-16=41
RY2
Pr.02-14=41
RY1
Pr.02-13=41
Pr.04-16 0 0 0 1
Pr.04-18 0 0 1 0
Pr.04-20 0 0 1 1
Pr.04-22 0 1 0 0
Pr.04-24 0 1 0 1
Pr.04-26 0 1 1 0
Pr.04-28 0 1 1 1
Pr.04-30 1 0 0 0
Pr.04-32 1 0 0 1
Pr.04-34 1 0 1 0
Pr.04-36 1 0 1 1
Pr.04-38 1 1 0 0
Pr.04-40 1 1 0 1
Pr.04-42 1 1 1 0
Pr.04-44 1 1 1 1
42 Crane Function
This function needs to be used with Pr02-32, Pr02-33, Pr02-34,
Pr02-57 and Pr.02-58.
The brake will be released when output frequency and current
reach the setting level after brake delay time.
When output frequency>= Pr02-34 and output current>= Pr02-33,
MO=42 will be activated after time setting at Pr02-32
When output frequency< Pr02-58, or output current <Pr02-57,
MO=42 will not be activate.
See crane output time sequence chart for reference
43
Motor Zero-speed
Output (Pr.02-47)
Active when motor actual speed is less than Pr.02-47.
44 Low Current Output This function needs to be used with Pr.06-71 ~ Pr.06-73
45
UVW Phase Magnet
Contractor ON/ OFF
Switch
1. Under FOCPG control mode, set MI=49 (drive enable) and
MO=45 (electromagnetic contractor On/Off switch), then the
magnetic contactor will follow the drive status to be On or Off.
2. For brake control, set MO=12 (mechanical brake release),
Pr.02-31=T1 sec (mechanical brake delay time); then
enable/disable DC braking by set 07-01 (DC brake current) to any
level except 0 and set Pr.07-02 = T2 (DC brake time at start up)
and Pr.07-03 = T2 (DC brake current at stop). It is recommend to
set T2 >T1 and try to activate brake control during zero-speed
status.