Yaskawa CIMR-PU2A0081 — настройки сброса данных и часов для управления устройствами [261/548]

Превью страниц Страница 261 / 548
Yaskawa CIMR-PU2A0211 [261/548] O4 17 real time clock setting
Setting 1: Reset kWh Data
Resets the kWh counter. The monitors U4-10 and U4-11 will display “0” after they are initialized. Setting o4-12 to 1 and
pressing the ENTER erases kWh data and returns the display to 0.
n
o4-13: Number of Run Commands Counter Initialization
Resets the Run command counter displayed in U4-02. Initializing the drive or cycling the power does not reset this monitor.
No. Name Setting Range Default
o4-13 Number of Run Commands Counter Initialization 0, 1 0
Setting 0: No Action
The Run command data are kept.
Setting 1: Number of Run Commands Counter
Resets the Run command counter. The monitor U4-02 will show 0. Setting o4-13 to 1 and pressing the ENTER key erases the
counter value and returns the display to 0.
n
o4-17: Real-Time Clock Setting
No. Name Setting Range Default
o4-17 Set/Reset Real-Time Clock 0 to 2 0
Setting 0: — —
No Setting (Default)
Setting 1: Set
When o4-17 is set to 1, the digital operator will show the Clock Adjustment display. In Clock Adjustment Mode the user can
adjust the Real-Time Clock.
Setting 2: Reset
When o4-17 is set to 2, the Real-Time Clock data is cleared. A TIM fault will occur until o4-17 is set to 1 and the Real-Time
Clock is set.
n
o4-20: Time Display Format
No. Name Setting Range Default
o4-20 Time Display Format 0, 1 0
Sets the time display format.
Setting 0: 12-Hour
Setting 1: 24-Hour
5.10 o: Operator Related Settings