Yaskawa CIMR-PU2A0081 — настройки уровня обнаружения и частоты при низкой скорости [426/548]

Превью страниц Страница 426 / 548
Yaskawa CIMR-PU2A0138 [426/548] B l protection function
No.
(Addr.
Hex)
Name Description Values Page
L8-94
(73D)
LSo Detection Level at Low
Speed
Determines the detection level of pull-out at low speed. Default: 3%
Min.: 0
Max.: 10
250
L8-95
(73D)
Average LSo Frequency at
Low Speed
Sets the average number of times pull-out can occur at low speed. Default: 10 times
Min.: 1
Max.: 50
250
<1> Default setting is dependent on parameter o2-04, Drive Model Selection.
<2> Parameter setting value is not reset to the default value when the drive is initialized.
<3> Default setting is determined by the drive model:
Setting 2: Model code CIMR-Po2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242
Setting 0: Model code CIMR-Po2A0250 to 2A0415 and 4A0208 to 4A0675
B.8 L: Protection Function
426