u
Cooling Fan Component Names
WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after the
power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching any
components.
CAUTION! Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or moderate injury. Shut off the power
to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled down.
C
E
G
D
B
A
2A0018 to 2A0081
4A0007 to 2A0044
5A0003 to 5A0032
2A0110 to 2A0138
4A0058 to 4A0103
5A0041 to 5A0052
2A0169 to 2A0415
4A0139 to 4A0362
5A0062 to 5A0242
D
A
D
Figure 7.1 Cooling Fan Component Names
A Fan finger guard
B Fan guard
C Cable cover
D Cooling fan
E
– Fan bracket
F – Circulation fan base
G Circulation fan
H Circuit board cooling fan
I Circuit board cooling fan unit case
Figure 7.2 Cooling Fan Component Names (Continued)
u
Cooling Fan Replacement: 2A0018 to 2A0081, 4A0007 to 4A0044, and 5A0006 to 5A0032
WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious
personal injury. Before servicing the drive, disconnect all power to the equipment. The internal capacitor remains charged even after the
power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the drive before touching any
components.
CAUTION! Burn Hazard. Do not touch a hot drive heatsink. Failure to comply could result in minor or moderate injury. Shut off the power
to the drive when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled down.
NOTICE: Follow cooling fan replacement instructions. Improper fan replacement could cause damage to equipment. Make sure the fan is
facing upwards when installing the replacement fan
into the drive. Replace all fans when performing maintenance to help ensure maximum
useful product life.
7.4 Drive Cooling Fans
YASKAWA SIEP YAIP1U 01A AC Drive - P1000 Technical Manual
333
7
Periodic Inspection &
Maintenance
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com